Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann N Y Acad Sci ; 1525(1): 147-159, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37253679

RESUMO

Chronic impairment in the paretic ankle following stroke often requires that individuals use compensatory patterns such as asymmetric propulsion to achieve effective walking speeds needed for community engagement. Ankle exosuit assistance can provide ankle biomechanical benefit in the lab, but such environments inherently limit the amount of practice available. Community walking studies without exosuits can provide massed practice and benefit walking speed but are limited in their ability to assist proper mechanics. In this study, we combined the positive aspects of community training with those of exosuit assistance. We developed and evaluated a community Robotic Exosuit Augmented Locomotion (cREAL) program. Four participants in the chronic stage of stroke independently used our community ankle exosuit for walking in the community 3-5 days/week for 4 weeks. We performed lab evaluations before and after the 4-week program. Two participants significantly improved their unassisted paretic propulsion by an average of 27% after the program and walked on average 4001 steps/day more in the week following the program. Despite the small number of participants, this study provides preliminary evidence for the potential of exosuits to augment gait training and rehabilitation in the community.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Fenômenos Biomecânicos , Caminhada , Acidente Vascular Cerebral/terapia , Articulação do Tornozelo , Marcha
2.
Sci Rep ; 12(1): 11004, 2022 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-35768486

RESUMO

As we age, humans see natural decreases in muscle force and power which leads to a slower, less efficient gait. Improving mobility for both healthy individuals and those with muscle impairments/weakness has been a goal for exoskeleton designers for decades. In this work, we discover that significant reductions in the energy cost required for walking can be achieved with almost 50% less mechanical power compared to the state of the art. This was achieved by leveraging human-in-the-loop optimization to understand the importance of individualized assistance for hip flexion, a relatively unexplored joint motion. Specifically, we show that a tethered hip flexion exosuit can reduce the metabolic rate of walking by up to 15.2 ± 2.6%, compared to locomotion with assistance turned off (equivalent to 14.8% reduction compared to not wearing the exosuit). This large metabolic reduction was achieved with surprisingly low assistance magnitudes (average of 89 N, ~ 24% of normal hip flexion torque). Furthermore, the ratio of metabolic reduction to the positive exosuit power delivered was 1.8 times higher than ratios previously found for hip extension and ankle plantarflexion. These findings motivated the design of a lightweight (2.31 kg) and portable hip flexion assisting exosuit, that demonstrated a 7.2 ± 2.9% metabolic reduction compared to walking without the exosuit. The high ratio of metabolic reduction to exosuit power measured in this study supports previous simulation findings and provides compelling evidence that hip flexion may be an efficient joint motion to target when considering how to create practical and lightweight wearable robots to support improved mobility.


Assuntos
Exoesqueleto Energizado , Robótica , Tornozelo/fisiologia , Fenômenos Biomecânicos , Marcha/fisiologia , Humanos , Paresia , Caminhada/fisiologia
3.
IEEE Trans Med Robot Bionics ; 2(2): 165-175, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33748694

RESUMO

In individuals with motor impairments such as those post-stroke or with cerebral palsy, the function of the knee extensors may be affected during walking, resulting in decreased mobility. We have designed a lightweight, hinge-free wearable robot combining soft textile exosuit components with integrated rigid components, which assists knee extension when needed but is otherwise highly transparent to the wearer. The exosuit can apply a wide range of assistance profiles using a flexible multi-point reference trajectory generator. Additionally, we implemented a controller safety limit to address the risk of hyperextension stemming from the hinge-free design. The exosuit was evaluated on six healthy participants walking uphill and downhill on a treadmill at a 10° slope with a set of joint power-inspired assistance profiles. A comparison of sagittal plane joint angles between no exosuit and exosuit unpowered conditions validated the device transparency. With positive power assistance, we observed reduction in average positive knee biological power during uphill walking (left: 17.5 ± 3.21%, p = 0.005; right: 23.2 ± 3.54%, p = 0.008). These initial findings show promise for the assistive capability of the device and its potential to improve the quality of gait and increase mobility in clinical populations.

4.
Science ; 365(6454): 668-672, 2019 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-31416958

RESUMO

Walking and running have fundamentally different biomechanics, which makes developing devices that assist both gaits challenging. We show that a portable exosuit that assists hip extension can reduce the metabolic rate of treadmill walking at 1.5 meters per second by 9.3% and that of running at 2.5 meters per second by 4.0% compared with locomotion without the exosuit. These reduction magnitudes are comparable to the effects of taking off 7.4 and 5.7 kilograms during walking and running, respectively, and are in a range that has shown meaningful athletic performance changes. The exosuit automatically switches between actuation profiles for both gaits, on the basis of estimated potential energy fluctuations of the wearer's center of mass. Single-participant experiments show that it is possible to reduce metabolic rates of different running speeds and uphill walking, further demonstrating the exosuit's versatility.


Assuntos
Metabolismo Energético , Exoesqueleto Energizado , Marcha , Corrida , Caminhada , Adulto , Teste de Esforço , Quadril , Humanos , Masculino , Robótica
5.
Sci Rep ; 9(1): 9779, 2019 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-31278286

RESUMO

Different adaptation rates have been reported in studies involving ankle exoskeletons designed to reduce the metabolic cost of their wearers. This work aimed to investigate energetic adaptations occurring over multiple training sessions, while walking with a soft exosuit assisting the hip joint. The participants attended five training sessions within 20 days. They walked carrying a load of 20.4 kg for 20 minutes with the exosuit powered and five minutes with the exosuit unpowered. Percentage change in net metabolic cost between the powered and unpowered conditions improved across sessions from -6.2 ± 3.9% (session one) to -10.3 ± 4.7% (session five), indicating a significant effect associated with training. The percentage change at session three (-10.5 ± 4.5%) was similar to the percentage change at session five, indicating that two 20-minute sessions may be sufficient for users to fully adapt and maximize the metabolic benefit provided by the exoskeleton. Retention was also tested measuring the metabolic reduction five months after the last training session. The percent change in metabolic cost during this session (-10.1 ± 3.2%) was similar to the last training session, indicating that the adaptations resulting in reduced metabolic cost are preserved. These outcomes are relevant when evaluating exoskeletons' performance on naïve users, with a specific focus on hip extension assistance.


Assuntos
Adaptação Fisiológica , Metabolismo Energético/fisiologia , Exoesqueleto Energizado , Articulação do Quadril/metabolismo , Robótica/instrumentação , Robótica/métodos , Caminhada/fisiologia , Biotecnologia/métodos , Seguimentos , Marcha/fisiologia , Voluntários Saudáveis , Humanos , Masculino , Militares , Estados Unidos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...